Difference between revisions of "ESXi - 6.7 nvme"

From Da Nerd Mage Wiki
Jump to navigation Jump to search
 
(27 intermediate revisions by the same user not shown)
Line 1: Line 1:
= nvme =
VMware NVMe driver esxcli extensions
VMware NVMe driver esxcli extensions


Line 8: Line 7:
* '''get'''
* '''get'''
: Get NVMe device information
: Get NVMe device information
:* <code>esxcli nvme device get '''CMD_OPTIONS'''</code>
:* <code>esxcli nvme device get '''OPTIONS'''</code>
  '''CMD_OPTIONS'''
  '''OPTIONS'''
   -A|--adapter=<str>    Adapter to operate on (required)
   -A|--adapter=<str>    Adapter to operate on (required)


Line 15: Line 14:
* '''list'''
* '''list'''
: List all controllers on the device if namespace is not specified, otherwise list all controllers the namespace attached
: List all controllers on the device if namespace is not specified, otherwise list all controllers the namespace attached
:* <code>esxcli nvme device controller list '''CMD_OPTIONS'''</code>
:* <code>esxcli nvme device controller list '''OPTIONS'''</code>
  '''CMD_OPTIONS'''
  '''OPTIONS'''
   -A|--adapter=<str>    Adapter to operate on (required)
   -A|--adapter=<str>    Adapter to operate on (required)
   -n|--namespace=<str>  Namespace ID attached. ID starts from 1
   -n|--namespace=<str>  Namespace ID attached. ID starts from 1
Line 28: Line 27:


==== aec ====
==== aec ====
* '''BORK'''
: OOGABOOGA
:* <code>esxcli nvme device feature WOOT BORK</code>
* '''get'''
* '''get'''
: Get NVMe device feature async event configuration information
: Get NVMe device feature async event configuration information
:* <code>esxcli nvme device feature aec get</code>
:* <code>esxcli nvme device feature aec get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
* '''set'''
* '''set'''
: Set NVMe device feature async event configuration information
: Set NVMe device feature async event configuration information
:* <code>esxcli nvme device feature aec set</code>
:* <code>esxcli nvme device feature aec set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -w|--fwnotices=<long> an asynchronous event notification is sent to the host for a Firmware
                        Activation Starting event, 0 for false, 1 for true, 0 will be passed as
                        default value, if not set
  -m|--nsnotices=<long> an asynchronous event notification is sent to the host for a Namespace
                        Attribute change, 0 for false, 1 for true, 0 will be passed as default
                        value, if not set
  -S|--save            save the attribute
  -v|--value=<long>    SMART health critical warnings bitmap to be set, refer to Figure 79, NVMe
                        1.2 SPEC (required)


get          Get NVMe device feature async event configuration information
set          Set NVMe device feature async event configuration information
==== apst ====
==== apst ====
get          Get NVMe device feature autonomous power state transition information
* '''apst'''
: Get NVMe device feature autonomous power state transition information
:* <code>esxcli nvme device feature apst get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
==== ar ====
==== ar ====
get           Get NVMe device feature arbitration information
* '''get'''
  set           Set NVMe device feature arbitration information
: Get NVMe device feature arbitration information
:* <code>esxcli nvme device feature ar get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
* '''set'''
: Set NVMe device feature arbitration information
:* <code>esxcli nvme device feature ar set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Arbitration Burst value to be set (required)
  -x|--value2=<long>    Low Priority Weight value to be set (required)
  -y|--value3=<long>    Medium Priority Weight value to be set (required)
  -z|--value4=<long>    High Priority Weight value to be set (required)
 
==== er ====
==== er ====
get           Get NVMe device feature error recovery information
* '''get'''
  set          Set NVMe device feature error recovery information
: Get NVMe device feature error recovery information
:* <code>esxcli nvme device feature er get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
* '''Set'''
: Set NVMe device feature error recovery information
:* <code>esxcli nvme device feature er Set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -e|--enable=<long>    deallocated or unwritten logical block error enable value to be set, 0 for
                        false (disable), 1 for true (enable), 0 will be passed as default value, if
                        not set
  -n|--namespace=<str>  Namespace to operate on, 0 will be passed as default value, if not set
  -S|--save            save the attribute
  -v|--value=<long>    Time limited error recovery value to be set (required)
 
==== hi ====
==== hi ====
get           Get NVMe device feature host identifier information
* '''get'''
: Get NVMe device feature host identifier information
:* <code>esxcli nvme device feature hi get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
==== hmb ====
==== hmb ====
get           Get NVMe device feature host memory buffer information
* '''get'''
: Get NVMe device feature host memory buffer information
:* <code>esxcli nvme device feature hmb get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
==== ic ====
==== ic ====
get           Get NVMe device feature interrupt coalescing information
* '''get'''
  set           Set NVMe device feature interrupt coalescing information
: Get NVMe device feature interrupt coalescing information
:* <code>esxcli nvme device feature ic get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature interrupt coalescing information
:* <code>esxcli nvme device feature ic set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Aggregation threshold value to be set (required)
  -x|--value2=<long>    Aggregation time value to be set (required)
 
==== ivc ====
==== ivc ====
get           Get NVMe device feature interrupt vector configuration information
* '''get'''
  set           Set NVMe device feature interrupt vector configuration information
: Get NVMe device feature interrupt vector configuration information
:* <code>esxcli nvme device feature ivc get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature interrupt vector configuration information
:* <code>esxcli nvme device feature ivc set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Interrupt vector value to be set (required)
  -x|--value2=<long>    Coalescing disable value to be set, 0 for false (enable), 1 for true
                        (disable) (required)
 
==== kat ====
==== kat ====
get           Get NVMe device feature keep alive timer information
* '''get'''
  set           Set NVMe device feature keep alive timer information
: Get NVMe device feature keep alive timer information
:* <code>esxcli nvme device feature kat get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature keep alive timer information
:* <code>esxcli nvme device feature kat set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -t|--timeout=<long>  timeout value for the keep alive feature to be set (required)
 
==== lba ====
==== lba ====
  get           Get NVMe device feature LBA range type information
  * '''get'''
: Get NVMe device feature LBA range type information
:* <code>esxcli nvme device feature lba get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -n|--namespace=<str>  Namespace to operate on (required)
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
==== nq ====
==== nq ====
get           Get NVMe device feature number of queue information
* '''get'''
: Get NVMe device feature number of queue information
:* <code>esxcli nvme device feature nq get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
 
==== pm ====
==== pm ====
get           Get NVMe device feature power management information
* '''get'''
  set           Set NVMe device feature power management information
: Get NVMe device feature power management information
:* <code>esxcli nvme device feature pm get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature power management information
:* <code>esxcli nvme device feature pm set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Power state value to be set (required)
  -w|--workload=<long>  Workload Hint to be set, 0 will be passed as default value, if not set
 
==== spm ====
==== spm ====
get           Get NVMe device feature software progress marker information
* '''get'''
  set           Set software progress marker feature information, will clear Pre-boot Software Load Count (PBSLC) to 0
: Get NVMe device feature software progress marker information
:* <code>esxcli nvme device feature spm get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set software progress marker feature information, will clear Pre-boot Software Load Count (PBSLC) to 0
:* <code>esxcli nvme device feature spm set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
 
==== tt ====
==== tt ====
get           Get NVMe device feature temperature threshold information
* '''get'''
  set           Set NVMe device feature temperature threshold information
: Get NVMe device feature temperature threshold information
:* <code>esxcli nvme device feature tt get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature temperature threshold information
:* <code>esxcli nvme device feature tt set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -s|--sensor=<long>    Threshold temperature select value to be set, 0 will be passed as default
                        value, if not set
  -u|--under            Set under temperature threshold
  -v|--value=<long>    Temperature threshold value to be set (required)
 
==== vwc ====
==== vwc ====
get           Get NVMe device feature volatile write cache information
* '''get'''
  set           Set NVMe device feature volatile write cache information
: Get NVMe device feature volatile write cache information
:* <code>esxcli nvme device feature vwc get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature volatile write cache information
:* <code>esxcli nvme device feature vwc set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Volitale write cache enable value to be set, 0 for false (disable), 1 for
                        true (enable) (required)
 
==== wa ====
==== wa ====
get           Get NVMe device feature write atomicity information
* '''get'''
  set           Set NVMe device feature write atomicity information
: Get NVMe device feature write atomicity information
:* <code>esxcli nvme device feature wa get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -S|--select=<str>    specify which value of the attributes to return, "current", "default",
                        "saved"
* '''set'''
: Set NVMe device feature write atomicity information
:* <code>esxcli nvme device feature wa set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -S|--save            save the attribute
  -v|--value=<long>    Disable Normal value to be set, 0 for false (enable), 1 for true (disable)
                        (required)


=== firmware ===
=== firmware ===
activate     Commit downloaded firmware image to a specific slot
* '''activate'''
  download     Download firmware image to the device
: Commit downloaded firmware image to a specific slot
:* <code>esxcli nvme device firmware activate '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -a|--action=<long>    Activate action (required)
                          0: Downloaded image replaces the image indicated by the
                              firmware slot field. This image is not activated.
                          1: Downloaded image replaces the image indicated by the
                              firmware slot field. This image is activated at the next reset.
                          2: The image specified by the firmware slot field is
                              activated at the next reset.
                          3: The image specified by the firmware slot field is
                              requested to be activated immediately without reset.
  -s|--slot=<long>      Slot number. If the value specified is 0, then the controller shall choose
                        the firmware slot. (required)
* '''download'''
: Download firmware image to the device
:* <code>esxcli nvme device firmware download '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -f|--firmware=<str>  Firmware image path (required)


=== log ===
=== log ===
==== error ====
==== error ====
get           Get NVMe device error log information
* '''get'''
: Get NVMe device error log information
:* <code>esxcli nvme device log error get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -e|--elpe=<long>      Error log page entries. This value indicates the number of log entries you
                        wish to get. The maximum number of entries supported is device-specific.
                        (required)
 
==== fwslot ====
==== fwslot ====
get           Get NVMe device firmware slot log information
* '''get'''
: Get NVMe device firmware slot log information
:* <code>esxcli nvme device log fwslot get '''ADAPTER'''</code>
 
==== smart ====
==== smart ====
get           Get NVMe device SMART log information
* '''get'''
: Get NVMe device SMART log information
:* <code>esxcli nvme device log smart get '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -n|--namespace=<long> Namespace ID. If log page is supported on a per namespace basis this value
                        indicates the ID of namespace you wish to get log from. This parameter can
                        be omitted to request global log page.


=== namespace ===
=== namespace ===
attach        Attach namespace on NVMe device
* '''list'''
  create       Create namespace on NVMe device
: List namespace on NVMe device
  delete       Delete namespace on NVMe device
:* <code>esxcli nvme device namespace list '''ADAPTER'''</code>
  detach       Detach namespace on NVMe device
 
  format       Change namespace format
 
get          Get nvme namespace information
* '''get'''
  list          List namespace on NVMe device
: Get nvme namespace information
:* <code>esxcli nvme device namespace get '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -n|--namespace=<str>  ID of namespace to get information from. ID starts from 1 (required)
 
* '''create'''
: Create namespace on NVMe device
:* <code>esxcli nvme device namespace create '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -c|--capacity=<long> Namespace Capacity (required)
  -p|--dps=<long>      End-to-End Data Protection Type Settings (required)
  -f|--flbas=<long>    Formatted LBA Size (required)
  -m|--nmic=<long>      Namespace Multi-path IO and Namespace Sharing Capabilities (required)
  -s|--size=<long>      Namespace Size (required)
 
* '''delete'''
: Delete namespace on NVMe device
:* <code>esxcli nvme device namespace delete '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -n|--namespace=<str>  ID of namespace to delete, starts from 1 (required)
 
* '''attach'''
: Attach namespace on NVMe device
:* <code>esxcli nvme device namespace attach '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -c|--controller=<long>
                        Controller ID to attach. ID starts from 0 (required)
  -n|--namespace=<str>  Namespace ID to attach. ID starts from 1 (required)
 
* '''detach'''
: Detach namespace on NVMe device
:* <code>esxcli nvme device namespace detach '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -c|--controller=<long>
                        Controller ID to detach. ID starts from 0 (required)
  -n|--namespace=<str>  ID of namespace to detach. ID starts from 1 (required)
 
* '''format'''
: Change namespace format
:* <code>esxcli nvme device namespace format '''ADAPTER''' '''OPTIONS'''</code>
  '''OPTIONS'''
  -f|--format=<long>    LBA Format(LBAF) (required)
  -m|--ms=<long>        Metadata Settings(MS). 0: Metadata is transferred as part of a separate
                        buffer. 1: Metadata is transferred as part of an extended data LBA.
                        (required)
  -n|--namespace=<long> Namespace ID (required)
  -p|--pi=<long>        Protection Information(PI). 0: Protection information is not enabled. 1:
                        Protection information is enabled, Type 1. 2: Protection information is
                        enabled, Type 2. 3: Protection information is enabled, Type 3. (required)
  -l|--pil=<long>      Protection Information Location(PIL). 0: PI is transferred as the last
                        eight bytes of metadata, if PI is enabled. 1: PI is transferred as the
                        first eight bytes of metadata, if PI is enabled. (required)
  -s|--ses=<long>      Secure Erase Settings(SES). 0: No secure erase operation requested. 1: User
                        Data Erase. 2: Cryptographic Erase. (required)


=== register ===
=== register ===
get           Dump NVMe device registers
* '''get'''
: Dump NVMe device registers
:* <code>esxcli nvme device register get '''ADAPTER'''</code>


=== timeout ===
=== timeout ===
get           Get timeout value of IO timeout checker
* '''get'''
set           Set timeout value for IO timeout checker
: Get timeout value of IO timeout checker
:* <code>esxcli nvme device timeout get '''ADAPTER'''</code>
* '''set'''
: Set timeout value for IO timeout checker
:* <code>esxcli nvme device timeout set '''ADAPTER''' '''OPTIONS'''</code>
'''OPTIONS'''
  -t|--timeout=<long>  IO timeout seconds for internal checker. Maximum timeout value is 40. 0:
                        disable timeout checker. (required)


== driver ==
== driver ==
=== loglevel ===
=== loglevel ===
set           Set NVMe driver log level and debug level
* '''set'''
: Set NVMe driver log level and debug level
:* <code>esxcli nvme driver loglevel set '''OPTIONS'''</code>
'''OPTIONS'''
  -d|--debuglevel=<str> Debug level(hex int format). When log level is 5, this value is used to
                        manupulate NVMe driver parameter: nvme_dbg. This parameter can be omitted
                        to indicate value 0.
                          BIT_0:  Print ctrlr level log
                          BIT_1:  Print namespace level log
                          BIT_2:  Print queue level log
                          BIT_3:  Print IO command level log
                          BIT_4:  Print admin command level log
                          BIT_5:  Print management level log
                          BIT_6:  Print exception handler log
                          BIT_7:  Print split command log
                          BIT_13: Print timeout handler log
                          BIT_14: Print init/cleanup log
                          BIT_15: Print temp log
                          BIT_16: Dump SG array
                          BIT_17: Dump PRP
                          BIT_18: Dump cdb
                          BIT_19: Dump NVM command
                          BIT_20: Dump completion queue entry
                          BIT_21: Dump user passthru data
                          BIT_22: Dump namespace info
                          BIT_23: Dump timeout info
                          BIT_24: Dump smart log info
  -l|--loglevel=<long>  Log level. This value is used to manupulate NVMe driver parameter:
                        nvme_log_level.
                          1: error
                          2: warning
                          3: info
                          4: verbose
                          5: debug
                                        (required)

Latest revision as of 20:05, 10 February 2022

VMware NVMe driver esxcli extensions

device

  • list
List NVMe devices registered to VMware NVMe driver
  • esxcli nvme device list
  • get
Get NVMe device information
  • esxcli nvme device get OPTIONS
OPTIONS
 -A|--adapter=<str>    Adapter to operate on (required)

controller

  • list
List all controllers on the device if namespace is not specified, otherwise list all controllers the namespace attached
  • esxcli nvme device controller list OPTIONS
OPTIONS
 -A|--adapter=<str>    Adapter to operate on (required)
 -n|--namespace=<str>  Namespace ID attached. ID starts from 1

feature

  • cap
Get NVMe device feature supported capabilities information
  • esxcli nvme device feature cap ADAPTER
ADAPTER
 -A|--adapter=<str>    Adapter to operate on (required)

aec

  • get
Get NVMe device feature async event configuration information
  • esxcli nvme device feature aec get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature async event configuration information
  • esxcli nvme device feature aec set ADAPTER OPTIONS
OPTIONS
 -w|--fwnotices=<long> an asynchronous event notification is sent to the host for a Firmware
                       Activation Starting event, 0 for false, 1 for true, 0 will be passed as
                       default value, if not set
 -m|--nsnotices=<long> an asynchronous event notification is sent to the host for a Namespace
                       Attribute change, 0 for false, 1 for true, 0 will be passed as default
                       value, if not set
 -S|--save             save the attribute
 -v|--value=<long>     SMART health critical warnings bitmap to be set, refer to Figure 79, NVMe
                       1.2 SPEC (required)

apst

  • apst
Get NVMe device feature autonomous power state transition information
  • esxcli nvme device feature apst get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"

ar

  • get
Get NVMe device feature arbitration information
  • esxcli nvme device feature ar get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature arbitration information
  • esxcli nvme device feature ar set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Arbitration Burst value to be set (required)
 -x|--value2=<long>    Low Priority Weight value to be set (required)
 -y|--value3=<long>    Medium Priority Weight value to be set (required)
 -z|--value4=<long>    High Priority Weight value to be set (required)

er

  • get
Get NVMe device feature error recovery information
  • esxcli nvme device feature er get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • Set
Set NVMe device feature error recovery information
  • esxcli nvme device feature er Set ADAPTER OPTIONS
OPTIONS
 -e|--enable=<long>    deallocated or unwritten logical block error enable value to be set, 0 for
                       false (disable), 1 for true (enable), 0 will be passed as default value, if
                       not set
 -n|--namespace=<str>  Namespace to operate on, 0 will be passed as default value, if not set
 -S|--save             save the attribute
 -v|--value=<long>     Time limited error recovery value to be set (required)

hi

  • get
Get NVMe device feature host identifier information
  • esxcli nvme device feature hi get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"

hmb

  • get
Get NVMe device feature host memory buffer information
  • esxcli nvme device feature hmb get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"

ic

  • get
Get NVMe device feature interrupt coalescing information
  • esxcli nvme device feature ic get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature interrupt coalescing information
  • esxcli nvme device feature ic set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Aggregation threshold value to be set (required)
 -x|--value2=<long>    Aggregation time value to be set (required)

ivc

  • get
Get NVMe device feature interrupt vector configuration information
  • esxcli nvme device feature ivc get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature interrupt vector configuration information
  • esxcli nvme device feature ivc set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Interrupt vector value to be set (required)
 -x|--value2=<long>    Coalescing disable value to be set, 0 for false (enable), 1 for true
                       (disable) (required)

kat

  • get
Get NVMe device feature keep alive timer information
  • esxcli nvme device feature kat get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature keep alive timer information
  • esxcli nvme device feature kat set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -t|--timeout=<long>   timeout value for the keep alive feature to be set (required)

lba

* get
Get NVMe device feature LBA range type information
  • esxcli nvme device feature lba get ADAPTER OPTIONS
OPTIONS
 -n|--namespace=<str>  Namespace to operate on (required)
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"

nq

  • get
Get NVMe device feature number of queue information
  • esxcli nvme device feature nq get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"

pm

  • get
Get NVMe device feature power management information
  • esxcli nvme device feature pm get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature power management information
  • esxcli nvme device feature pm set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Power state value to be set (required)
 -w|--workload=<long>  Workload Hint to be set, 0 will be passed as default value, if not set

spm

  • get
Get NVMe device feature software progress marker information
  • esxcli nvme device feature spm get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set software progress marker feature information, will clear Pre-boot Software Load Count (PBSLC) to 0
  • esxcli nvme device feature spm set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute

tt

  • get
Get NVMe device feature temperature threshold information
  • esxcli nvme device feature tt get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature temperature threshold information
  • esxcli nvme device feature tt set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -s|--sensor=<long>    Threshold temperature select value to be set, 0 will be passed as default
                       value, if not set
 -u|--under            Set under temperature threshold
 -v|--value=<long>     Temperature threshold value to be set (required)

vwc

  • get
Get NVMe device feature volatile write cache information
  • esxcli nvme device feature vwc get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature volatile write cache information
  • esxcli nvme device feature vwc set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Volitale write cache enable value to be set, 0 for false (disable), 1 for
                       true (enable) (required)

wa

  • get
Get NVMe device feature write atomicity information
  • esxcli nvme device feature wa get ADAPTER OPTIONS
OPTIONS
 -S|--select=<str>     specify which value of the attributes to return, "current", "default",
                       "saved"
  • set
Set NVMe device feature write atomicity information
  • esxcli nvme device feature wa set ADAPTER OPTIONS
OPTIONS
 -S|--save             save the attribute
 -v|--value=<long>     Disable Normal value to be set, 0 for false (enable), 1 for true (disable)
                       (required)

firmware

  • activate
Commit downloaded firmware image to a specific slot
  • esxcli nvme device firmware activate ADAPTER OPTIONS
OPTIONS
 -a|--action=<long>    Activate action (required)
                          0: Downloaded image replaces the image indicated by the
                             firmware slot field. This image is not activated.
                          1: Downloaded image replaces the image indicated by the
                             firmware slot field. This image is activated at the next reset.
                          2: The image specified by the firmware slot field is
                             activated at the next reset.
                          3: The image specified by the firmware slot field is
                             requested to be activated immediately without reset.
 -s|--slot=<long>      Slot number. If the value specified is 0, then the controller shall choose
                       the firmware slot. (required)
  • download
Download firmware image to the device
  • esxcli nvme device firmware download ADAPTER OPTIONS
OPTIONS
 -f|--firmware=<str>   Firmware image path (required)

log

error

  • get
Get NVMe device error log information
  • esxcli nvme device log error get ADAPTER OPTIONS
OPTIONS
 -e|--elpe=<long>      Error log page entries. This value indicates the number of log entries you
                       wish to get. The maximum number of entries supported is device-specific.
                       (required)

fwslot

  • get
Get NVMe device firmware slot log information
  • esxcli nvme device log fwslot get ADAPTER

smart

  • get
Get NVMe device SMART log information
  • esxcli nvme device log smart get ADAPTER OPTIONS
OPTIONS
 -n|--namespace=<long> Namespace ID. If log page is supported on a per namespace basis this value
                       indicates the ID of namespace you wish to get log from. This parameter can
                       be omitted to request global log page.

namespace

  • list
List namespace on NVMe device
  • esxcli nvme device namespace list ADAPTER


  • get
Get nvme namespace information
  • esxcli nvme device namespace get ADAPTER OPTIONS
OPTIONS
 -n|--namespace=<str>  ID of namespace to get information from. ID starts from 1 (required)
  • create
Create namespace on NVMe device
  • esxcli nvme device namespace create ADAPTER OPTIONS
OPTIONS
 -c|--capacity=<long>  Namespace Capacity (required)
 -p|--dps=<long>       End-to-End Data Protection Type Settings (required)
 -f|--flbas=<long>     Formatted LBA Size (required)
 -m|--nmic=<long>      Namespace Multi-path IO and Namespace Sharing Capabilities (required)
 -s|--size=<long>      Namespace Size (required)
  • delete
Delete namespace on NVMe device
  • esxcli nvme device namespace delete ADAPTER OPTIONS
OPTIONS
 -n|--namespace=<str>  ID of namespace to delete, starts from 1 (required)
  • attach
Attach namespace on NVMe device
  • esxcli nvme device namespace attach ADAPTER OPTIONS
OPTIONS
 -c|--controller=<long>
                       Controller ID to attach. ID starts from 0 (required)
 -n|--namespace=<str>  Namespace ID to attach. ID starts from 1 (required)
  • detach
Detach namespace on NVMe device
  • esxcli nvme device namespace detach ADAPTER OPTIONS
OPTIONS
 -c|--controller=<long>
                       Controller ID to detach. ID starts from 0 (required)
 -n|--namespace=<str>  ID of namespace to detach. ID starts from 1 (required)
  • format
Change namespace format
  • esxcli nvme device namespace format ADAPTER OPTIONS
OPTIONS
 -f|--format=<long>    LBA Format(LBAF) (required)
 -m|--ms=<long>        Metadata Settings(MS). 0: Metadata is transferred as part of a separate
                       buffer. 1: Metadata is transferred as part of an extended data LBA.
                       (required)
 -n|--namespace=<long> Namespace ID (required)
 -p|--pi=<long>        Protection Information(PI). 0: Protection information is not enabled. 1:
                       Protection information is enabled, Type 1. 2: Protection information is
                       enabled, Type 2. 3: Protection information is enabled, Type 3. (required)
 -l|--pil=<long>       Protection Information Location(PIL). 0: PI is transferred as the last
                       eight bytes of metadata, if PI is enabled. 1: PI is transferred as the
                       first eight bytes of metadata, if PI is enabled. (required)
 -s|--ses=<long>       Secure Erase Settings(SES). 0: No secure erase operation requested. 1: User
                       Data Erase. 2: Cryptographic Erase. (required)

register

  • get
Dump NVMe device registers
  • esxcli nvme device register get ADAPTER

timeout

  • get
Get timeout value of IO timeout checker
  • esxcli nvme device timeout get ADAPTER
  • set
Set timeout value for IO timeout checker
  • esxcli nvme device timeout set ADAPTER OPTIONS
OPTIONS
 -t|--timeout=<long>   IO timeout seconds for internal checker. Maximum timeout value is 40. 0:
                       disable timeout checker. (required)

driver

loglevel

  • set
Set NVMe driver log level and debug level
  • esxcli nvme driver loglevel set OPTIONS
OPTIONS
 -d|--debuglevel=<str> Debug level(hex int format). When log level is 5, this value is used to
                       manupulate NVMe driver parameter: nvme_dbg. This parameter can be omitted
                       to indicate value 0.
                          BIT_0:  Print ctrlr level log
                          BIT_1:  Print namespace level log
                          BIT_2:  Print queue level log
                          BIT_3:  Print IO command level log
                          BIT_4:  Print admin command level log
                          BIT_5:  Print management level log
                          BIT_6:  Print exception handler log
                          BIT_7:  Print split command log
                          BIT_13: Print timeout handler log
                          BIT_14: Print init/cleanup log
                          BIT_15: Print temp log
                          BIT_16: Dump SG array
                          BIT_17: Dump PRP
                          BIT_18: Dump cdb
                          BIT_19: Dump NVM command
                          BIT_20: Dump completion queue entry
                          BIT_21: Dump user passthru data
                          BIT_22: Dump namespace info
                          BIT_23: Dump timeout info
                          BIT_24: Dump smart log info
 -l|--loglevel=<long>  Log level. This value is used to manupulate NVMe driver parameter:
                       nvme_log_level.
                          1: error
                          2: warning
                          3: info
                          4: verbose
                          5: debug
                                       (required)